Accessible routes connecting play components shall provide a clear width complying with 1008.2.4. (ii) If the first certificate of occupancy for the facility is issued after January 26, 1993. One side of the wheelchair space shall adjoin an accessible route when in the load and unload position. Water closets and toilet compartments for childrens use shall comply with 604.9. Ramp runs connecting ground level play components shall have a running slope not steeper than 1:16. Amusement rides that are controlled or operated by the rider shall not be required to comply with 234.3. EXCEPTION: Dining surfaces and work surfaces for childrens use shall be permitted to comply with 902.4. For example, a fuel pier may contain boat slips, and this type of short term slip would be included in determining compliance with 235.2. Accessibility statements are important for several reasons: In some situations, you may be required to provide an accessibility statement, such as public bodies in countries that implement the EU Web Accessibility Directive . Examples of ground level play components may include spring rockers, swings, diggers, and stand-alone slides. Cross slope is the slope of the surface perpendicular to the direction of travel. Not more than 10 percent of guest rooms required to provide mobility features complying with 806.2 shall be used to satisfy the minimum number of guest rooms required to provide communication features complying with 806.3. Areas of refuge shall not be required in detention and correctional facilities. (2) For the purposes of this section, alterations to windows, hardware, controls, electrical outlets, and signage shall not be deemed to be alterations that affect the usability of or access to an area containing a primary function. Clear floor or ground spaces, turning spaces, and accessible routes are permitted to overlap within play areas. Where three or fewer entry points are provided for soft contained play structures, at least one entry point shall be on an accessible route. Additionally, the Equal Employment Opportunity Commission (EEOC) implements title I of the ADA which requires non-discrimination in the workplace. An accessible route must be provided to these rides. Building directories, menus, seat and row designations in assembly areas, occupant names, building addresses, and company names and logos shall not be required to comply with 216. EXCEPTION: Where a single clear floor space complying with 305 positioned for parallel approach is provided between two beds, a clear floor or ground space shall not be required on both sides of a bed. Points of entry to bleacher seating may include, but are not limited to, cross aisles, concourses, vomitories, and entrance ramps and stairs. Bathtub shower spray units shall deliver water that is 120F (49C) maximum. Isolated or temporary interruptions in service due to maintenance or repairs may be unavoidable; however, failure to take prompt action to effect repairs could constitute a violation of Federal laws and these requirements. The vertical distance is 10 feet (3050 mm) between the elevation where the gangway departs the landside connection and the elevation of the pier surface at the lowest water level. Extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent ramp run. The requirements in Section 806.2 do not include requirements that are common to all accessible spaces. (ii) If it is not feasible to provide physical access to an historic property in a manner that will not threaten or destroy the historic significance of the building or facility, alternative methods of access shall be provided pursuant to the requirements of 35.150. Devices that do not require handsets are easier to use by people who have a limited reach. Signs shall be provided in accordance with 216 and shall comply with 703. While dispersion is not required, the flexibility it provides can be a critical factor in ensuring cost effective compliance with applicable civil rights laws, including titles II and III of the ADA and Section 504 of the Rehabilitation Act of 1973, as amended. 2. Sample accessibility statement - GOV.UK An area of a building or facility containing a major activity for which the building or facility is intended is a primary function area. (B) A series of buildings on a common site, either under common ownership or common control or developed either as one project or as a series of related projects, housing five or more sales or rental establishments. The required van accessible designation is intended to be informative, not restrictive, in identifying those spaces that are better suited for van use. The clear width of a ramp run and, where handrails are provided, the clear width between handrails shall be 36 inches (915 mm) minimum. While typical elevators are not designed to be used during an emergency evacuation, evacuation elevators are designed with standby power and other features according to the elevator safety standard and can be used for the evacuation of individuals with disabilities. Transfer systems complying with 1008.3 shall be permitted to connect elevated play components in water. Each arm of the T shall be clear of obstructions 12 inches (305 mm) minimum in each direction and the base shall be clear of obstructions 24 inches (610 mm) minimum. 5. Elevator operation shall be automatic. Automatic doors and automatic gates shall comply with 404.3. (2) New construction and alterations subject to 36.401 or 36.402 shall comply either with the 1991 Standards or with the 2010 Standards if the date when the last application for a building permit or permit extension is certified to be complete by a State, county, or local government (or, in those jurisdictions where the government does not certify completion of applications, if the date when the last application for a building permit or permit extension is received by the State, county, or local government) is on or after September 15, 2010, and before March 15, 2012, or if no permit is required, if the start of physical construction or alterations occurs on or after September 15, 2010, and before March 15, 2012. In that case, any portion of the facility that can be made accessible shall be made accessible to the extent that it is not structurally impracticable. 4. Each has different advantages and disadvantages that can help determine which system is best for a given application. The running slope of walking surfaces shall not be steeper than 1:20. Signs provided at entrances to parking facilities informing drivers of clearances and the location of van accessible parking spaces can provide useful customer assistance. For example: the number of storage spaces required to comply with these requirements must provide accessible Routes complying with Section 206; accessible means of egress complying with Section 207; Parking Spaces complying with Section 208; and, where provided, other public use or common use elements and facilities such as toilet rooms, drinking fountains, and telephones must comply with the applicable requirements of this document. The surface of the bottom tread shall extend to a water depth of 18 inches (455 mm) minimum below the stationary water level. The test methods in this standard address access for children and adults who may traverse the surfacing to aid children who are playing. Where a large play area includes two or more composite play structures designed for the same age group, the total number of elevated play components on all the composite play structures must be added to determine the additional number and types of ground level play components that must be provided on an accessible route. The following examples of accessibility statements were created using this generator tool: This accessibility statement generator tool is designed for use in different contexts and jurisdictions. Guest rooms required to provide mobility features shall comply with 806.2. Front loading machines shall have the bottom of the opening to the laundry compartment located 15 inches (380 mm) minimum and 36 inches (915 mm) maximum above the finish floor. EXCEPTIONS: 1. Advisory 502.7 Relationship to Accessible Routes. Bus stop boarding and alighting areas shall be connected to streets, sidewalks, or pedestrian paths by an accessible route complying with 402. Where possible, designers are encouraged to locate the transfer device seat no higher than 17 to 19 inches (430 to 485 mm) above the load and unload surface. Raised characters shall be installed in accordance with 703.4. For example, awnings and their supporting structures cannot reduce the minimum required vertical clearance. ANSI/BHMA A156.10-1999 applies to power operated doors for pedestrian use which open automatically when approached by pedestrians. Handrail extensions specified by 505.10.1 shall not be required at the bottom landing serving a sloped entry. Low-energy and power-assisted doors shall comply with ANSI/BHMA A156.19 (1997 or 2002 edition) (incorporated by reference, see Referenced Standards in Chapter 1). Urinals shall be the stall-type or the wall-hung type with the rim 17 inches (430 mm) maximum above the finish floor or ground. Doctors offices, independent clinics, or other facilities not located in hospitals are not considered hospital outpatient facilities for purposes of this document. Section 508 Accessibility Statement - U.S. Department of State Revolving doors, revolving gates, and turnstiles shall not be part of an accessible route. When the door to the toilet room is placed directly in front of the water closet, the water closet cannot overlap the required maneuvering clearance for the door inside the room. A clear floor space complying with 305 positioned for a forward approach shall be provided. Advisory 101.1 General. Characters shall contrast with their background with either light characters on a dark background or dark characters on a light background. Visible notification devices shall be provided to alert room occupants of incoming telephone calls and a door knock or bell. In transportation facilities, in addition to the requirements of 217.4.1 through 217.4.4, where at least one public pay telephone serves a particular entrance to a bus or rail facility, at least one public TTY shall be provided to serve that entrance. For example, both a bank lobby and the banks employee areas such as the teller areas and walk-in safe are primary function areas. Accessible routes serving floating fishing piers and platforms shall be permitted to use Exceptions 1, 2, 5, 6, 7 and 8 in 1003.2.1. However, residential facilities must also comply with the requirements of this document. 2. Advisory 304.2 Floor or Ground Surface Exception. Competency. EXCEPTIONS: 1. Carpet edge trim shall comply with 303. Structures and equipment directly associated with the actual processes of construction are not required to be accessible as permitted in 203.2. Consider providing visual contrast on tread nosings, or at the leading edges of treads without nosings, so that stair treads are more visible for people with low vision. Advisory 206.2.3 Multi-Story Buildings and Facilities. The Department of Justice ADA regulations also allow public entities to use alternative methods when altering qualified historic buildings or facilities in the rare situations where the State Historic Preservation Officer determines that it is not feasible to provide physical access using the exceptions permitted in Section 202.5 without threatening or destroying the historic significance of the building or facility. EXCEPTION: Shower and sauna doors in guest rooms that are not required to provide mobility features complying with 806.2 shall not be required to comply with 404.2.3. EXCEPTION: Wheelchair spaces in team or player seating areas serving areas of sport activity shall not be required to comply with 221.2.3. EXCEPTION: If at least 50 percent of the elevated play components are connected by a ramp and at least 3 of the elevated play components connected by the ramp are different types of play components, the play area shall not be required to comply with 240.2.1.2. Other requirements for doors and doorways in Section 404 do not apply to guest rooms not required to provide mobility features. Between 9 inches (230 mm) and 27 inches (685 mm) above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches (150 mm) in height. 2. Advisory 234.1 General. The rear edge of the L portion of the seat shall be 1 inches (38 mm) maximum from the wall and the front edge shall be 14 inches (355 mm) minimum and 15 inches (380 mm) maximum from the wall. If a cash register is provided at the sales or service counter, locate the accessible counter close to the cash register so that a person using a wheelchair is visible to sales or service personnel and to minimize the reach for a person with a disability. 2. The Importance of Having a Web Accessibility Statement Control panels shall be on a side wall, 12 inches (305 mm) minimum from any adjacent wall. 5. The model accessibility statement will provide a 'datamodel' comparable to the model produced in WCAG-EM to help harmonize consistent reporting. These requirements apply generally to newly designed and constructed amusement rides and attractions. Changes in level are not permitted. Public pay telephones required to accommodate portable TTYs shall be equipped with a shelf and an electrical outlet within or adjacent to the telephone enclosure. Toilet and bathing rooms that are provided as part of a patient or resident sleeping room shall comply with 603. Wheelchair accessible compartments for childrens use shall be 60 inches (1525 mm) wide minimum measured perpendicular to the side wall, and 59 inches (1500 mm) deep minimum for wall hung and floor mounted water closets measured perpendicular to the rear wall. First, look at how competent the supplier is. Vertical, center, or side aisles adjoining bleacher seating that are stepped or tiered are not considered entry points. Shower stalls that are 60 inches (1525 mm) wide and have no curb may increase the usability of a bathroom because the shower area provides additional maneuvering space. At least one accessible entrance to each tenancy in a facility shall comply with 404. Advisory 704.3 Volume Control Telephones. 7. Telephones, where provided within cells, shall have volume controls complying with 704.3. Where multiple sports fields or courts are provided, an accessible route is required to each field or area of sport activity. The exception does not apply to those rides where patrons may cause the ride to make incidental movements, but where the patron otherwise has no control over the ride. Edge protection shall not be required on the sides of ramp landings having a vertical drop-off of 1/2 inch (13 mm) maximum within 10 inches (255 mm) horizontally of the minimum landing area specified in 405.7. 2. Advisory 203.12 Animal Containment Areas. Advisory 233.3.4.1 Alterations to Vacated Buildings. Clearances at boat slips and on boarding piers at boat launch ramps shall comply with 1003.3. In facilities with residential dwelling units, at least 5 percent, but no fewer than one unit, of the total number of residential dwelling units shall provide mobility features complying with 809.2 through 809.4 and shall be on an accessible route as required by 206. In standard roll-in type showers without seats, the shower head and operable parts can be located on any of the three walls of the shower without adversely affecting accessibility. EXCEPTION: Where space on an existing car operating panel precludes tactile markings to the left of the controls, markings shall be placed as near to the control as possible. EXCEPTION: Parking spaces used exclusively for buses, trucks, other delivery vehicles, law enforcement vehicles, or vehicular impound shall not be required to comply with 208 provided that lots accessed by the public are provided with a passenger loading zone complying with 503. EXCEPTION: Where sloped entries are provided, the surfaces shall not be required to be slip resistant. Operable parts shall be operable with one hand and shall not require tight grasping, pinching, or twisting of the wrist. ANSI/BHMA A156.19-2002 American National Standard for Power Assist and Low Energy Power Operated Doors (see 404.3, 408.3.2.1, and 409.3.1). 7. Recreational boating facilities shall comply with 235. EXCEPTION: In assembly areas, aisle ramps adjacent to seating and not serving elements required to be on an accessible route shall not be required to comply with 405. Bus boarding and alighting areas shall provide a clear length of 96 inches (2440 mm), measured perpendicular to the curb or vehicle roadway edge, and a clear width of 60 inches (1525 mm), measured parallel to the vehicle roadway. These systems or devices should be designed to be reliable and sturdy. Where spectators are expected to remain seated during events, spectators in wheelchair spaces shall be afforded lines of sight complying with 802.2.1. Permanent seats at the head end of the bathtub shall be 15 inches (380 mm) deep minimum and shall extend from the back wall to or beyond the outer edge of the bathtub. Recessed ashtrays should not be placed near elevator call buttons so that persons who are blind or visually impaired do not inadvertently contact them or their contents as they reach for the call buttons. (4) Costs associated with relocating an inaccessible drinking fountain. accessible routes serving miniature golf facilities shall comply with Chapter 4 except as modified by 1007.2. Then we will provide guidance for every one of them, describing what the information is and how it can be reported including the data format. The floor or ground surface of wheelchair spaces shall comply with 302. Advisory 225.2.2 Self-Service Shelving. Shelves shall be 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor or ground. EXCEPTIONS: 1. Transfer-type showers are not permitted in lieu of a roll-in shower with a seat, and the exceptions in sections 608.3 and 608.4 for residential dwelling units are not permitted. In order for mirrors to be usable by people who are ambulatory and people who use wheelchairs, the top edge of mirrors should be 74 inches (1880 mm) minimum from the floor or ground. At least one accessible route shall be provided within the site from accessible parking spaces and accessible passenger loading zones; public streets and sidewalks; and public transportation stops to the accessible building or facility entrance they serve. Where a series of transfers are required to reach the amusement ride seat, each vertical transfer should not exceed 8 inches (205 mm). The grab bar located at the transfer platform shall not obstruct transfer. EXCEPTIONS: 1. In addition, accessible routes shall not be required to connect stories or mezzanines where multi-story buildings or facilities are exempted by 206.2.3 Exceptions 1 through 7. At least one tactilely discernible input control shall be provided for each function. Some may have batteries, motors, and electrical systems that when submerged in water may cause damage to the personal mobility device or wheelchair or may contaminate the water. Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches (1525 mm) maximum above the finish floor or ground surface, measured from the baseline of the highest tactile character. (5) Noncomplying new construction and alterations. Where facilities with residential dwelling units are provided by entities subject to regulations issued by the Department of Housing and Urban Development (HUD) under Section 504 of the Rehabilitation Act of 1973, as amended, such entities shall provide residential dwelling units with mobility features complying with 809.2 through 809.4 in a number required by the applicable HUD regulations. Providing a golf car passage will permit a person that uses a golf car to practice driving a golf ball from the same position and stance used when playing the game. Surfaces of transfer walls shall not be sharp and shall have rounded edges. Although the minimum width of the clear pier space is 60 inches (1525 mm), it is recommended that piers be wider than 60 inches (1525 mm) to improve the safety for persons with disabilities, particularly on floating piers. Where lavatories are provided, at least one shall comply with 606 and shall not be located in a toilet compartment. In residential facilities containing residential dwelling units required to provide mobility features complying with 809.2 through 809.4, parking spaces provided in accordance with 208.2.3.1 shall be located on the shortest accessible route to the residential dwelling unit entrance they serve. There shall be no projections into the required clear opening width lower than 34 inches (865 mm) above the finish floor or ground. Accessible routes serving boarding piers at boat launch ramps shall be permitted to use the exceptions in 1003.2.2. This generator tool allows you to enter different types of information to create accessibility statements for your particular situation. Free-standing objects mounted on posts or pylons shall overhang circulation paths 12 inches (305 mm) maximum when located 27 inches (685 mm) minimum and 80 inches (2030 mm) maximum above the finish floor or ground. The floor or ground surface of wheelchair spaces shall have a slope not steeper than 1:48 when in the load and unload position. Grab bars shall be installed 6 inches (150 mm) maximum from adjacent walls. It is also recommended that where two or more means of access are provided, they not be provided in the same location in the pool. Ground surfaces shall be inspected and maintained regularly and frequently to ensure continued compliance with ASTM F 1951. Note to Reader: The Department of Transportations ADA standards include additional requirements for the location of accessible routes: 206.3 Location. Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum.